<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Control</title>
<title_fa>مجله کنترل</title_fa>
<short_title>JoC</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://joc.kntu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-8345</journal_id_issn>
<journal_id_issn_online>2538-3752</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/joc</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1396</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2017</year>
	<month>9</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>2</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>طراحی و پیاده سازی دبی‌سنج فراصوت چهارمسیره با استفاده از روش تفاضل زمانی </title_fa>
	<title>Design and Fabrication of a Four-path Ultrasonic Flowmeter using the Time-difference Method</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research paper</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;یک دبی&#8204;سنج فراصوت چهار مسیره با نصب فرستنده/گیرنده&#8204;های امواج فراصوت بر روی یک لوله 8 اینچی طراحی و ساخته شد. با عبور کنترل شده سیال ازدرون دبی&#8204;سنج ساخته شده، سرعت سیال در چهار لایه مختلف با استفاده از روش تفاضل زمانی(Time-difference) اندازه گیری شد. با استفاده از روش انتگرال گیری عددی به روش گاوس-لژاندر و اعمال تقریب مهندسی، نرخ شارش سیال بدست آمد. با مقایسه پاسخ دبی&#8204;سنج ساخته شده با پاسخ یک دبی&#8204;سنج تجاری مرجع، صحت عملکرد سیستم در نرخ جریانهای مختلف مورد آزمایش قرار گرفت. همچنین با مقایسه پاسخ آن با پاسخ یک دبی&#8204;سنج فراصوت تک مسیره معادل، خطای اندازه گیری آنها مقایسه گردید. نتیجه بیانگر خطای متوسط کمتر از 3% در نرخ سرعتهای بالاتر از m/s5/0 و خطای متوسط 15% در سرعتهای کمتر از m/s 3/0 بود. متوسط خطای متوسط دبی&#8204;سنج تک مسیره در تمام سرعتها حدود20% بالاتر از خطای سرعت سنج چهار مسیره بود.&lt;/div&gt;
</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;A four-path ultrasonic flow meter was designed and fabricated by using of ultrasonic transmitter/receivers on an 8-inch pipe. By passing fluid through the flowmeter at a controlled rate, the velocity was measured in different layers using the time-difference method. Fluid flow rate was estimated by Gauss-Legendre numerical integration method and applying of the engineering approximation. By comparison of the results with the actual measurement done by a calibrated reference flow meter, the accuracy of the system was tested at various flow rates. It also was compared with the measurement of an equivalent one-path ultrasonic flowmeter, and the measurement errors were calculated. The test result represented that, the average error of measurement is less than 3% at the speeds of 0.5 m/s and more. The average error was more than 15% at the speeds below 0.3 m/s. The measurement error of the one-path flowmeter was 20% more than that of four path one.&lt;/div&gt;
</abstract>
	<keyword_fa>دبی‌سنج, فراصوت,  روش تفاضل زمانی, روش گاوس-لژاند</keyword_fa>
	<keyword>flow meter, ultrasonic, time difference method, method of Gauss-Legendre</keyword>
	<start_page>55</start_page>
	<end_page>62</end_page>
	<web_url>http://joc.kntu.ac.ir/browse.php?a_code=A-10-606-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad</first_name>
	<middle_name></middle_name>
	<last_name>Orvatinia</last_name>
	<suffix></suffix>
	<first_name_fa>محمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>عروتی نیا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>orvatinia@ictfaculty.ir</email>
	<code>10031947532846004048</code>
	<orcid>10031947532846004048</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>The Ministry of Communications and Information Technology, Tehran, Iran</affiliation>
	<affiliation_fa>وزارت ارتباطات و فناوری اطلاعات</affiliation_fa>
	 </author>


	<author>
	<first_name>Abbas</first_name>
	<middle_name></middle_name>
	<last_name>Gharibi</last_name>
	<suffix></suffix>
	<first_name_fa>عباس</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>غریبی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>a.gharibi@nioc-iotc.com</email>
	<code>10031947532846004049</code>
	<orcid>10031947532846004049</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>, The Ministry of petroleum</affiliation>
	<affiliation_fa>شرکت پایانه های نفتی ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
