<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Journal of Control</title>
<title_fa>مجله کنترل</title_fa>
<short_title>JoC</short_title>
<subject>Engineering &amp; Technology</subject>
<web_url>http://joc.kntu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>2008-8345</journal_id_issn>
<journal_id_issn_online>2538-3752</journal_id_issn_online>
<journal_id_pii></journal_id_pii>
<journal_id_doi>10.61186/joc</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid></journal_id_sid>
<journal_id_nlai></journal_id_nlai>
<journal_id_science></journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1401</year>
	<month>10</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2023</year>
	<month>1</month>
	<day>1</day>
</pubdate>
<volume>16</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>کنترل سطح آب درام بویلر های نیروگاهی با استفاده از الگوریتم کنترل تطبیقی جدید با در نظر گرفتن کارایی حلقه کنترلی و افزایش طول عمرشیر کنترلی (مطالعه موردی کنترل سطح آب درام IP نیروگاه سیکل ترکیبی قم)</title_fa>
	<title>Power plant boilers drum water level control using a new adaptive control algorithm by considering the control loop performance and increasing life cycle of its control valve (case study: Qom combined cycle power plant boiler IP drum water level control)</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>كاربردي</content_type_fa>
	<content_type>Review paper</content_type>
	<abstract_fa>&lt;div style=&quot;text-align: justify;&quot;&gt;یکی&#8204; از حلقه&#8204;های&#8204;کنترلی مهم درنیروگاه&#8204;های&#8204;حرارتی، حلقه&#8204;کنترل سطح آب درام بویلر است. عدم عملکرد مطلوب این حلقه، باعث کاهش راندمان، آسیب احتمالی به تجهیزات و یا حتی&amp;nbsp; بروز توقف اضطراری واحد می&#8204;شود. از آنجایی که سطح آب درام بویلر با اعمال فرمان به یک شیر آب&#8204;تغذیه کنترل&#8204; می&#8204;شود، فرمان کنترلی اعمال شده باید دارای حداقل نوسان باشد تا عمر شیر&#8204;آب &#8204;تغذیه در اثر استهلاک کم نشود. بدین منظور در این مقاله، یک الگوریتم کنترلی تطبیقی جدید ارائه می&#8204;شود که علاوه بر کاهش استهلاک شیرکنترلی، همچنین اثر اغتشاش ناشی از تغییرات تقاضای بخار را کاهش داده و عوامل غیرخطی ترمودینامیکی درام بویلر به منظور حفظ سطح آب درام پیرامون مقدار مطلوب بهره&#8204;بردار را در نظر گرفته و نسبت به تغییر پارمترهای مدل دینامیکی درام بویلر مقاوم باشد. به منظور ارزیابی کارایی الگوریتم ارائه شده در شرایط واقعی، این الگوریتم بر روی مدل دینامیکی سطح آب درامIP بویلر شماره۱۱ نیروگاه&#8204;سیکل&#8204;ترکیبی&#8204;قم اجرا شده&#8204;است. نتایج حاصل از شبیه&#8204;سازی این روش کنترلی و مقایسه آن با عملکرد کنترل&#8204;کننده کلاسیک موجود نیروگاه، کنترل&#8204;کننده مدلغزشی وکنترل&#8204;کننده PID مرتبه کسری خود تنظیم در شرایط یکسان، نشان می&#8204;دهد که روش ارائه شده از دو جنبه حفظ سطح آب درام حول نقطه&#8204;تنظیم&amp;nbsp; تحت شرایط مختلف وکاهش استهلاک شیر آب تغذیه دارای عملکرد بهتری است.&lt;/div&gt;</abstract_fa>
	<abstract>&lt;div style=&quot;text-align: justify;&quot;&gt;Drum water level control loop is one of the most important control loops in any steam power plant. In case of unacceptable performance of this loop, we have reduction of power plant efficiency, failure of equipment or maybe power plant shut down. Since in this loop, we use the feed water control valve as final control element, is very important to have minimum swing as possible in order to increase of the life cycle control valve. In this paper, to achieve this objective, a new adaptive control algorithm is proposed which have good life cycle control valve, to reduce the disturbance effect due to steam demand variation, to consider drum thermodynamic nonlinear characteristics and to robust to dynamical parameters variation. In order to evaluate the performance of proposed algorithm in real industrial situation, this algorithm is applied to Qom combined cycle power plant boiler No 11 drum water level dynamical model. The simulation results using this algorithm and power plant classical controller, sliding mode control, Auto-tune fraction order PID show the proposed algorithm regarding the life cycle of feed water control valve and control loop performance in different conditions has better performance compared to these algorithms.&lt;/div&gt;</abstract>
	<keyword_fa>کنترل سطح آب درام, بویلر نیروگاهی, کارایی حلقه کنترل, طول عمر شیر کنترلی, الگوریتم کنترل تطبیقی</keyword_fa>
	<keyword>Drum water level control, Power plant boiler, Control loop performance, Control valve lifetime, Adaptive control algorithm.</keyword>
	<start_page>15</start_page>
	<end_page>26</end_page>
	<web_url>http://joc.kntu.ac.ir/browse.php?a_code=A-10-1081-1&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>Mohammad Hossein</first_name>
	<middle_name></middle_name>
	<last_name>Hashemi</last_name>
	<suffix></suffix>
	<first_name_fa>محمدحسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>mhasheme4@gmail.com</email>
	<code>10031947532846009056</code>
	<orcid>10031947532846009056</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of electrical engineering , Shahid Beheshti University</affiliation>
	<affiliation_fa>گروه برق کنترل، دانشگاه شهید بهشتی،تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Keyvan</first_name>
	<middle_name></middle_name>
	<last_name>Zahedi</last_name>
	<suffix></suffix>
	<first_name_fa>کیوان</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>زاهدی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>keyvanzahedi73@gmail.com</email>
	<code>10031947532846009057</code>
	<orcid>10031947532846009057</orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Faculty of electrical engineering , Shahid Beheshti University</affiliation>
	<affiliation_fa>گروه برق کنترل، دانشگاه شهید بهشتی،تهران، ایران</affiliation_fa>
	 </author>


	<author>
	<first_name>Mohsen</first_name>
	<middle_name></middle_name>
	<last_name>Montazeri</last_name>
	<suffix></suffix>
	<first_name_fa>محسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>منتظری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>m_montazeri@sbu.ac.ir</email>
	<code>10031947532846009058</code>
	<orcid>10031947532846009058</orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Faculty of electrical engineering , Shahid Beheshti University</affiliation>
	<affiliation_fa>گروه برق کنترل، دانشگاه شهید بهشتی،تهران، ایران</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
